Proportional valve types for different applications

07 Oct.,2024

 

Proportional valve types for different applications

When it comes to Proportional Valves, they are well-suited to a number of different applications in machinery, basic processes and hydro-pneumatic systems.  They provide compact and cost effective solutions for controlling pressure or flow at low flow rates.

If you are looking for more details, kindly visit Huade Hydraulic.

With so much differentiation and sources of supply, it is important to ensure you are picking the correct proportional valve to suit your application. This article will describe the important considerations you must take into account when selecting the correct proportional valve.

Proportional Valve Set Points

The first things to consider are:

  • What are the maximum and minimum pressures that the valve is likely to experience?
  • What are the flow ranges the valve is likely to experience?

Static Set Point

Pressure or Flow will be Fixed With Infrequent Changes

Typical Applications:

  • Spot welding &#; where a valve is used to control pressure to a cylinder that applies the pinching force. The pressure will be set dependant on the material type and thickness being welded and will remain fixed until the machine is set up for a different material.
  • Leak testing &#; where a fixed pressure is applied to a component to check for soundness. The pressure will generally be fixed for a specific type of component but has provision for adjustment when the application is changed.

Dynamic Set Point

Pressure or Flow will Change at a High Frequency

Typical Applications:

  • Pressure control valves connected to cylinders operating a flight simulator. Signals from the simulator control system constantly adjust the pressure in the cylinders to move the simulator cabin.
  • Material testing where the pressure output of a valve is steadily increased until the material under test fails.

Step-By-Step Point:

Pressure or Flow will change but at a Low Frequency

Typical Applications:

  • A filling system where, as the container being filled approaches the required fill level, the flow rate is adjusted down so that the final filling happens at a lower rate.
  • The control of gas to a burner on a cooker. This application would require different flow rates of gas dependant on the amount of heat required.

Adjusting Set Points

Another consideration when selecting a valve may be the means by which you want to adjust the setting, whether that is a set pressure or a set flow rate. As discussed above, the set point can be static, dynamic or &#;step by step&#;.

  • Some valves enable you to adjust the set point by sending an analogue control signal over the power cables or by using some sort of fieldbus communications.
  • Others have a local interface
  • Some enable you to communicate with the device via a PC and an RS 232 interface (this enables a far greater degree of tuning and optimisation to take place.

Actuation of Operation of your Proportional Valve

Engineers should also consider the type of operation they require. Different operation methods for proportional valves could be:

  • Proportional solenoids: valve position is adjusted based on a varying voltage across the coil. The higher the voltage the greater the magnetic current and the more the valve spindle moves. It tends to give short response times and has an extremely low hysteresis.
  • Pulsed solenoids: uses small solenoid valves that load and unload pressure in a control chamber, allowing the valve to open and close.
  • Piezoelectric elements: Their highly compact size makes piezoelectric operated valves ideal for use in portable and table top machines such as medical equipment, measuring systems and gas analysers. The valves have very low power consumption and can even be operated by batteries or solar cells.
  • Pneumatically operated and controlled by a positioner: When looking at larger capacities and larger flow rates it may be necessary to move to a valve fitted with a positioner. The positioner acts as a pilot, enabling air to enter and vent from a diaphragm or a cylinder which enables the much larger valve to operate.

The intention of this article is to discuss some of the factors that must be considered when specifying and purchasing proportional valves. For more information, please leave comments below, post a technical question in the Solution Centre or us at [ protected].

Proportional Solenoid Valves: Types, Uses, Features and ...

Proportional Solenoid Valves

Please fill out the following form to submit a Request for Quote to any of the following companies listed on



Introduction

This article takes an in-depth look at proportional solenoid valves.

You will learn more about topics such as:

  • What is a Proportional Solenoid Valve?
  • Uses for Proportional Solenoid Valves
  • How Proportional Solenoid Valves are Made
  • Types of Proportional Solenoid Valves
  • And much more&#;

Chapter One &#; What is a Proportional Solenoid Valve?

A proportional solenoid valve controls fluid flow by adjusting a restrictor. This regulation impacts various process systems, affecting parameters such as level, pressure, temperature, weight, thickness, humidity, density, color, and viscosity. The valve's actuator is a solenoid that allows for variable positioning of the valve.

A traditional solenoid valve is a two-way valve that can be open or closed. A proportional solenoid valve provides the same functions as a traditional solenoid but with greater control over the positioning of the plunger and spool. They have a wide range of positions to meet the needs of any flow control application.


To regulate the flow rate, proportional solenoid valves vary the position of the valve plunger. The positioning of the plunger is electromagnetically operated and controlled by a magnetic field that is created by power supplied to the solenoid coil using the input it receives from the driver. The positions of a proportional solenoid valve are open and closed, both of which are held in position without a source of power.

In simple terms, a proportional solenoid valve works against a spring to determine the size of the valve opening. When working with fluids, their characteristics are changed by flow, pressure, temperature, and purity, requiring changes to the spool position. Additionally, changes in the pressure and thickness of a fluid affect the speed of an actuator.

While servo valves are excellent for precise fluid characteristic monitoring, proportional solenoid valves offer comparable accuracy at a significantly lower cost. They enhance machine performance by reducing pressure on output lines.

Chapter Two &#; What are the common uses for proportional solenoid valves?

Proportional solenoid valves are uniquely designed for remote activation, enabling precise control of air, gas, or liquid flow. They are commonly employed in engines and hydraulically operated machinery, as well as in more specialized applications such as managing power and compressed air in marine environments, construction, food processing, woodworking, material handling, and metalworking industries.

Key characteristics of proportional solenoid valves include their linearity, frequency response, and hysteresis. These factors are crucial in determining the valve's accuracy in flow control, with hysteresis reflecting the delay in response.

Solenoid Valves in Irrigation

In irrigation systems, a proportional solenoid valve regulates water flow and automates sprinkler operations. The valve is first calibrated to determine its opening and closing range. After calibration, the valve operates automatically based on the pressure differential, opening when upstream pressure exceeds downstream pressure.

Proportional solenoid valves can be pre-set to either open or close positions before activation.


Valves and Coolant

A coolant proportional solenoid valve regulates the flow of antifreeze and cleaning fluids within a cooling system. It features an adjustment mechanism, such as a screw or knob, to set the extent of valve opening upon actuation. When installed, these valves remain closed until they are activated.

Electronically controlled coolant proportional solenoid valves can modify the direction of coolant flow, regulate flow rates, and proportionally distribute the coolant volume.


Braking Systems

Brake proportional solenoid valves manage the pressure delivered to the rear brakes, helping to avoid rear wheel lock-up and ensuring smooth and safe stopping. These valves are essential because rear brakes typically need less pressure than front brakes, making proportional control necessary.

Brake proportional solenoid valves come in various types, tailored to different braking systems, and are often custom-designed to fit specific system requirements.


Applications in Medicine

In the medical sector, proportional solenoid valves are essential for managing the flow of various liquids, where precision and accuracy are critical. These valves are valued for their ability to provide reliable control and enhance safety in medical applications.

Applications in medicine include administering precise doses and regulating the release of liquids in medical devices and systems.


Hydraulic Equipment

Various types of proportional solenoid valves are employed in hydraulic systems, such as flow, directional, and pressure relief valves. These valves are favored in hydraulic applications due to their ability to maintain multiple positions within the rated stroke of the solenoid. Unlike basic on-off solenoids, proportional solenoid valves feature a more advanced design, allowing for finer control.

In hydraulic systems, which are often part of a closed-loop setup, proportional solenoid valves play a crucial role in ensuring precise control. Common configurations include bolt, screw, and three-pin designs. Regardless of their specific type, these valves are essential for managing the flow, pressure, and direction of hydraulic fluids.


Solenoid Valves in a Furnace

The gas supply to a furnace must be precisely controlled to avoid overheating the furnace and maintain a controlled temperature in a residence or business. Proportional solenoid valves regulate the gas supply to ensure proper temperature control. A differential temperature signal gives feedback regarding the gas flow when the desired temperature is reached. The proportional solenoid valve shuts off gas flow at that time.


Ventilation Machine

Ventilation machines are designed to manage and deliver respiratory air to patients, crucial for those experiencing breathing difficulties due to medical conditions or injuries. These devices must ensure that air is supplied with the precise pressure, flow rate, and oxygen concentration necessary for effective treatment. Accurate flow regulation is critical to ensure the patient's safety and well-being.

Proportional solenoid valves are engineered with exact voltage specifications to achieve the precise control required by ventilation machines. Through meticulous calculations, these valves help maintain the necessary conditions for optimal respiratory support.


Leak Detection

Detecting leaks is crucial across various applications since both fluid and gas leaks can lead to significant damage. Proportional solenoid valves are used to apply pressure in a controlled manner to test for leaks within a system. In certain setups, these valves are integrated with the control panel, allowing them to shut off the supply automatically upon detecting a leak.


Leading Manufacturers and Suppliers

    Chapter Three &#; What are the different types of proportional solenoid valves?

    The position of a proportional solenoid valve is regulated by the voltage applied to its coil. As the voltage increases, so does the magnetic force, causing the valve's spindle to move further. Unlike standard solenoids, proportional solenoids feature a regulating magnet that allows for precise control over the spool's position.

    In systems employing proportional solenoid valves, the technology is termed "proportional control." These valves are engineered to manage load variations in advanced fluid control systems. Their ability to adjust positions helps to gradually manage the forces acting on the actuator, enhancing system stability.

    Directional Control Valves

    Proportional directional control valves play a critical role in hydraulic systems. These valves can either be direct-acting or pilot-operated, and they are often used in closed-loop configurations. By managing the flow of fluids to various actuators, proportional solenoid-operated directional valves offer a versatile solution. Unlike traditional valves, these control valves reduce the need for numerous solenoids by allowing continuous adjustment to regulate flow volumes efficiently.

    Want more information on hydraulic proportional valves? Feel free to contact us.


    Flow Control Valves

    Proportional solenoid flow control valves regulate flow rates by adjusting the position of the valve's plunger. This mechanism allows for precise control over variables such as pressure, fluid levels, and temperature. The movement of the plunger is determined by the electrical power supplied to the solenoid coil, which alters its stroke. A pulse width modulator (PWM) is typically used to manage the power delivered to the valve.


    Pressure Relief Valves

    Pressure relief proportional solenoid valves are a remote method for increasing or decreasing pressure. They are used to limit the amount of pressure in a system using electronically transmitted signals. Proportional solenoid pressure relief valves are designed to operate at various pressure ranges to increase controllability. They can be used for PTO, transmission, pressure, and hydraulic control.


    Pressure-Reducing Valves

    A proportional solenoid pressure-reducing valve maintains a stable pressure on the downstream side, irrespective of variations in upstream pressure. These valves negate the necessity for an extra pressure relief valve. By adjusting pressure based on the solenoid's current, they operate independently of the input pressure. When not energized, the valve keeps the tank connection fully open, allowing for minimal pressure in the system.


    Pressure Reducing

    A proportional solenoid pressure-reducing valve ensures consistent pressure on the secondary side of the system, even if the pressure on the primary side fluctuates. These valves remove the requirement for an extra pressure relief valve. Pressure reduction is based on the solenoid current, allowing the valve to function independently from inlet pressure. When deactivated, the valve fully opens the connection to the tank, maintaining very low pressure.


    3-Way Reducing Valves

    The 3-way proportional pressure-reducing valve controls pressure by converting a single input into a proportional output pressure signal. It is mounted on a subplate, offering excellent accuracy and responsiveness. The valve adjusts its opening based on flow requirements, ensuring that system pressure remains stable. Additionally, it is designed to release excess pressure when a sudden spike occurs.

    These 3-way proportional solenoid reducing valves are widely used in applications such as hydraulic systems, turbochargers, transmissions, oil pumps, and braking systems.


    Canister Proportional Solenoid Valves

    A canister proportional solenoid valve manages the flow of vapors from the canister to the engine manifold, ensuring precise control. This valve offers accurate regulation of fluid flow, streamlining system operations. It serves multiple purposes, such as controlling canister diaphragm flow and regulating vacuum, delivering enhanced performance while also reducing costs.


    Piston Proportional Solenoid Valves

    Piston proportional solenoid valves operate by opening when energized and closing when de-energized. Energizing the coil activates the pilot valve, which relieves pressure from above the piston. This pressure relief allows the piston to rise off its seat due to the plunger's action. When the coil is de-energized, a spring closes the pilot valve, and a bleed passage is exposed to let pressure build up above the piston, pushing it back into its seat.

    For optimal performance, a piston proportional solenoid valve should be mounted horizontally with the solenoid enclosure positioned vertically on top. The valve is capable of operating across a range of differential pressures from zero to maximum.


    Pilot Proportional Solenoid Valves

    Pilot proportional solenoid valves rely on the differential pressure between the inlet and outlet, with the inlet pressure being higher. These valves feature a two-way pilot solenoid that uses either a piston or a diaphragm to seal the main valve seat. The diaphragm&#;s design requires a pressure drop across the main valve seat to remain open, facilitated by the solenoid plunger.

    When the solenoid is activated, its plunger opens the pilot orifice, allowing pressure from above the diaphragm to escape to the outlet side via the pilot channel in the main body. This creates an imbalance, causing the main line pressure to lift the diaphragm off the main seat.

    When the solenoid is deactivated, the pilot orifice closes, and the full line pressure is applied to the top of the diaphragm. The bleed orifice in the diaphragm directs pressure to the inlet side of the valve, generating enough force to close the valve seat.

    These pilot proportional solenoid valves are designed for continuous operation and can remain energized without risk of overheating. Their unique design allows them to incorporate line pressure into their functionality. The two proportional solenoids manage the pilot orifice, adjusting the pressure differential between the inlet and outlet sides of the diaphragm and valve seat.


    Chapter Four &#; How Proportional Solenoid Valves Are Made?

    A proportional solenoid valve adjusts flow and pressure based on electrical input, making it suitable for applications with fluctuating pressure and flow conditions. These valves are used to replace fixed flow or pressure valves, enhancing system accuracy and efficiency while minimizing the number of components needed.

    Proportional solenoid valves are commonly employed in scenarios requiring precise control over acceleration and deceleration. They help mitigate flow variations that can lead to fluctuations in both inlet and outlet pressure.

    Proportional Solenoid Valve Spool

    A proportional solenoid valve spool features "V" notches that enable precise control over fluid flow, actuator speed, and direction. This design allows a single valve to manage both the direction and speed of the actuator. What distinguishes a proportional solenoid valve is that the spool does not move to its final position in one swift action; instead, it adjusts incrementally.


    Driver Card

    A proportional solenoid valve operates based on commands from a programmable logic controller (PLC) or a computer. The control is managed by a pulse width modulator (PWM) driver card, which can also regulate other devices. The PLC sends current to the valve&#;s solenoid, causing the spool to move due to electromechanical forces. The driver employs a comparator with hysteresis to generate a pulsed switch signal, resulting in a consistent amplitude PWM current signal.


    Solenoid Coil

    The solenoid coil is a crucial component of a proportional solenoid valve, consisting of a coil, tube, and armature. It is constructed from copper wire, which is categorized into Classes F, H, and N, each capable of withstanding different temperature ranges from 311 °F (155 °C) to 392 °F (200 °C). When the valve is energized, the solenoid coil generates a magnetic field that causes the plunger to move proportionally.


    Plunger

    The plunger in a proportional solenoid valve is the component that interfaces with the controlled device, regulating the opening and closing of the valve. Plungers can come in different shapes, such as square or rectangular bars, or round pistons. When the valve is activated electromagnetically, the plunger moves in response to signals from the PLC, adjusting proportionally to control the valve's operation.


    Feedback Transducer

    As the spool moves, its position is monitored by a feedback transducer. This device measures the spool's position and sends the data to the driver card. The driver card then compares this data with the input from the PLC. If there is a discrepancy between the two sets of data, the driver card adjusts the spool&#;s position until the feedback matches the PLC&#;s input.


    Chapter Five &#; How a Proportional Solenoid Valve Works?

    Standard solenoid valves primarily function to open or close a valve or activate a switch, operating through electromagnetic means with limited control capabilities. In contrast, proportional solenoid valves offer greater controllability, allowing for precise regulation and monitoring of valve positions. They also track load accumulation to alleviate stress on mechanical components.

    The operations of a proportional solenoid valve can be performed by a servo motor, which is more expensive than a proportional solenoid valve. Since a PLC or computer can easily control proportional solenoid valves, they are a less expensive method for process control.

    Foundational Principle of a Proportional Solenoid Valve

    A proportional solenoid valve operates on the principle that varying the DC current allows for precise control of the solenoid plunger's position. To manage the static friction of the plunger, the input signal is converted into a pulse width modulation (PWM) signal through control electronics.

    PWM is a technique used to regulate the power delivered to electrical devices, generated by a digital integrated circuit (IC) such as a microcontroller. For proportional solenoid valves, the PWM frequency typically ranges from 25 Hz to 200 Hz, allowing the valve to respond effectively across the control duty cycle.

    Several factors affect PWM operation, with temperature being a key one. Heat buildup in the PWM coil can alter its performance, making it crucial for the coils to compensate for increased resistance due to rising temperatures. This compensation depends on the operating conditions of the proportional solenoid coil.

    With digital control, a proportional solenoid valve can achieve and maintain its full stroke position. The valve's position is adjusted from zero to full stroke based on the time-averaged current applied. The voltage applied to the plunger is toggled on and off, causing the plunger to oscillate with a fast, low-amplitude movement, creating a balanced state to ensure consistent sliding friction.

    Operationally, a proportional solenoid valve functions similarly to a standard on/off solenoid. When the solenoid coil is energized, it creates an electromagnetic field that moves the armature. For a proportional valve, voltage applied at both ends of the solenoid coil drives the valve open. The balance between the electromagnetic field and the spring force stabilizes the valve position.

    Any changes in the control input will adjust the valve opening to align with the desired parameters.

    The system of a proportional solenoid valve performs the following functions:

    • Temperature Control: A current change occurs when the solenoid valve is heated.
    • Start Time Control: A start time switch provides control to prevent damage to an operation during start-up.
    • Signal Control: If the input signal is less than the predetermined value, the valve closes.
    • Extremes Control: The values of the coil can be set for an operation&#;s extremes.
    • Remote Control: Remote control is one of the major advantages of a proportional solenoid valve.
    • Parameter Control: The parameters for the proportional solenoid valve can be set on a PLC or computer.
    • Safety: If the power to the application is cut off, the valve closes.

    Process control systems can be costly and prone to high failure rates. However, integrating a proportional solenoid control valve with an advanced controller and sensors offers precise control at a significantly lower cost compared to traditional methods.

    The primary advantage of proportional solenoid valves is their ability to provide exceptional control over flow rates with high precision and accuracy. They are suitable for a wide range of machine cycles at variable speeds, enhancing safety and operational efficiency. The selection of a proportional solenoid valve depends on factors such as pressure variations, back pressure range, the type of fluid being controlled, temperature ranges of both the process and the environment.

    Duty Cycle

    An important consideration for any equipment is its duty cycle, which refers to the duration it remains operational. Duty cycles, or duty factors, are typically represented as percentages or ratios. For proportional solenoid valves, duty cycles are expressed as percentages. A higher duty cycle percentage indicates that the valve receives a greater amount of power.

    Pulse Width Modulation (PWM) measures the actual duration the valve is activated, recorded in milliseconds. It tracks only the time the signal is on, and this measurement is used to calculate the valve's duty cycle.

    Duty Cycle Formula

    The duty cycle is calculated using the formula: (time off / (time on + time off)) × 100.

    A proportional solenoid valve adjusts flow from zero to maximum based on its duty cycle, which ranges from 0% to 100%. Depending on the inlet flow rates and electrical input, these valves can maintain an open position ranging from 4% to 100%.


    Advantages of Proportional Solenoid Valves

    Proportional solenoid valves are essential for fluid control in contemporary fluid systems. They offer numerous advantages over traditional methods, making them a key component in fluid management and production processes.

    Some of their advantages include:

    • Regulation of load build-up, reducing loads on mechanical components
    • Replacement of manual valves
    • Simplification of the structures of hydraulic and pneumatic systems
    • Long-term quality performance
    • Automation of adjustment variables
    • Enhancement of energy efficiency
    • Regulation of speed, position, power, and mixture ratios

    The primary advantage of proportional solenoid valves is their precise control over pressure. This capability makes them highly popular and often the preferred choice for process regulation.

    Conclusion

    • A proportional solenoid valve is a method for controlling fluid flow through the use of a restrictor. In certain operations, the regulation of the flow rate affects process systems with regard to level, pressure, temperature, weight, thickness, humidity, density, color, and viscosity.
    • To regulate the flow rate, proportional solenoid valves vary the position of the valve plunger. The positioning of the plunger is controlled by a magnetic field that is created by power supplied to the solenoid coil.
    • A common use for proportional solenoid valves is to control fluid flow in engines and hydraulically operated machinery. In more specialized functions, they control the flow of power and compressed air in the marine, construction, food processing, woodworking, material handling, and metalworking industries.
    • The position of a proportional solenoid valve is adjusted according to the voltage that crosses the coil. The higher the voltage, the greater will be the magnetic current and the more the valve spindle moves.
    • A proportional solenoid valve has controllability and the ability to regulate and monitor the positioning of a valve.

    Leading Manufacturers and Suppliers

      If you are looking for more details, kindly visit hydraulic system relief valve.