A Tablet coating machine is used to provide a coating over uncoated tablets, which protects them from environmental moisture, and chemical degradation and masks the bitter taste of the drug, etc. Also, the Coating machine shall have provision for film coating (Aqueous / Non-Aqueous) and sugar coating with interchangeable type coating pans of different capacities.
Working principles of tablet coating machines:Tablet coating equipment simply worked by applying solution spray on the compressed tablet in a bed that will move horizontally and vertically. A uniform flow of heated air will dry the coat of the tablet and facilitate the evaporation of solvents.
Brief:Compressed tablet spinning involves putting the tablets in a drum and rotating it in an orbital way. As the drum spins, a nozzle sprays a coating solution Aqueous / Non-Aqueous) onto the tablets. Automation ensures there are accuracy and an even and uniform spray on the tablets. This has baffles installed in a drum at a particular angle and turn tables facilitating sideways even spraying of the tablets, while the spaying and rotation continue, the machine pumps hot air into the drum which results in the rapid coating of the solution. After all the tablets have a uniform coating, the spinning and spraying stopped, and the tablets then proceed to the drying section.
Types of tablet coating machines:
There are many types of coating machines in the market. Mostly we categorize coating machines on the basis of their pan & working principles. Below are the types of coating machines
Standard coating pan
Pellegrini pan
Immersion sword system
Immersion tube system
Perforated coating pan
Accela-Cota
Hi-coater systems
Driacoater
Glatt coater
Fluidized bed or air suspension coater
High-pressure airless systems
Low-pressure air atomized systems
The coating system must be able to monitor and control the below-listed key process parameters
Parameter
Range
Accuracy
Spray rate/gun
20-90 g/min
± 5 g/min
Pan speed (rpm)
0.5-20rpm
±1rpm
Airflow (Inlet air fan speed rpm)
m3/hour
m3/hour
Inlet air temperature
25-90ºC
±3ºC
Outlet air temperature
25-70ºC
±3ºC
Product temperature
25-70ºC
±3ºC
Inlet air humidity (desiccant system)
3-10 g/Kg
±1 g/Kg
The angle of spray guns
0, 20, 40, 60, 80 -90deg
NA
Atomizing air pressure (MPA)
1- 6 Mpa
0.1 Mpa
Distance of spray guns to tablets bed
15-30 mm
NA
Key Quality Attributes:
The product to be processed in the required coating system must comply with the specs of the below key quality attributes.
Parameter
Range
weight gain percentage for film coating
1-5%
Weight gain percentage for Sugar coater
50-100%
Quantity of film coat applied on tablet total surface area
3.0-5.0mg/cm2 It depends upon the % weight build-up and tablet surface.
Major Components of Coating Machine:Drive Component:
Coating Pan:
Feature Details Pan Gross Volume L Drum Diameter mm Drum Diameter (Inches) Inches Min Working Volume L Min Working Capacity Kg Max Working Volume L Max Working Capacity Kg
Spray gun:
Damper:
Pump & it’s manifold:
The capacity of a tablet coating machine in the pharmaceutical industry can be calculated using the following formula:
Capacity = (Tablet weight x Batch size x Coating time) / Coating efficiency
Here are the steps to calculate the capacity:
By following these steps and using the formula, you can calculate the capacity of a tablet coating machine in the pharmaceutical industry.
Critical Parameters of a tablet coating machineThe critical parameters of a tablet coating machine in the pharmaceutical industry are:
By closely monitoring and controlling these critical parameters, a pharmaceutical manufacturer can ensure that their tablet coating machine is producing tablets with a high-quality, uniform coating that meets the required specifications.
Air Processing unit (APU) with Heat exchanger:
Filter Set EU4/EU7/EU13
Pre-Filter
Fine Filter
HEPA Filter
Equipped with a differential pressure transmitter for indication on HMI.
APU consists of a heating coil to heat the filtered air. The steam valves should automatically be controlled with the help of the software PID controller working in concordance with the PLC commands and the user input temperature set on the HMI of the machine.
The present temperature of Inlet air shall be displayed on the variation in actual and the set temperature should not be more than + 3.0 °C. Temperatures (with PT100): +/- 1 % of the measuring range
The machine has auto spray cutoff provision interlock with inlet temperature (when inlet temperature breaches the upper and lower temperature set point for inlet air).
The maximum set value for inlet temperature will be 90°C (higher than this is acceptable).
Dust collector:
Wet Scrubber:
A wet scrubber is used by transferring solid particles from a gas stream to a liquid, wet scrubber procedures remove them from the stream. The energy required to touch the gas stream with the scrubber liquid determines how effectively a wet scrubber collects particles.
CIP System:
Control System:
The machine has a fully automated control panel
The recipe should have set points for the following (Not limited to):
There are lots of manufacturers worldwide who manufacture Tablet Coating machines, some of the best manufacturers are below:
Answer: coating machine is used to do the coating of the solution on the compressed tablet.
What is the principle of coating?
Answer: The principle of the coating Machine is the spraying of the solution on the tablet with moving bed tablets, and the solvent is spayed to it using a stream of hot air to this moving pan.
How many types of coating machines are there?Answer: There are two types of coating tablets in pharmaceuticals which are sugar coating & polymer film coating Machine.
What is the purpose of a tablet coating machine in pharmaceuticals?Answer: A tablet coating machine is used to apply a thin layer of coating material onto tablets, serving purposes such as improving appearance, taste, stability, and controlled-release properties.
How does a tablet coating machine work?Answer: A tablet coating machine typically consists of a rotating drum or pan where tablets are placed. The coating material is sprayed onto the tablets while they tumble in the drum. The machine may have features to control temperature, airflow, and spray rate for uniform coating application.
What are the types of coating materials used in tablet coating machines?Answer: Tablet coating materials can include polymers, sugar-based substances, and other coating agents depending on the desired properties and requirements of the tablets.
What is the importance of uniform coating application?Answer: Uniform coating application ensures consistent quality and effectiveness of the tablets, as it ensures that each tablet receives the appropriate amount of coating material.
How is the drying process achieved in tablet coating machines?Answer:After the coating material is applied, the tablets undergo a drying process using heated air. The machine’s design and airflow patterns facilitate the efficient removal of moisture from the coating, ensuring a dry and stable final product.
Can tablet coating machines apply multiple layers of coating?Answer: Yes, tablet coating machines can apply multiple layers of coating if necessary. This allows for the creation of complex formulations or specific release profiles.
How is the coating solution supplied to the tablet coating machine?Answer: The coating solution is supplied to the tablet coating machine through a spraying system that includes a spray gun or nozzles. The solution is typically stored in a reservoir connected to the spraying system.
What factors are controlled during the tablet coating process?Answer: During the tablet coating process, factors such as temperature, airflow, spray rate, and the angle of the drum or pan can be controlled to ensure optimal coating results and efficiency.
What are the challenges associated with tablet coating?Answer: Challenges in tablet coating can include achieving uniform coating thickness, preventing tablet damage or sticking, controlling the drying process effectively, and maintaining batch-to-batch consistency.
How important is the selection of a tablet coating machine for pharmaceutical manufacturers?Answer: The selection of a tablet coating machine is crucial for pharmaceutical manufacturers as it directly impacts the quality, efficiency, and productivity of tablet production. Factors such as capacity, coating flexibility, ease of cleaning, and compliance with regulatory standards should be considered when choosing a tablet coating machine.
For more technical details, best equipment vendor comparison, or any type of documentation. (SOP,DQ,IQ,OQ,PQ etc.) Plase contact:admin@flairpharma.com
You may also click for guidelines here.
Learn the working and principle of tablet coating machine used for different types of coatings on tablets.
A tablet coating machine is an equipment that coats the external surface of a tablet using a thin film of coating material. Working principle of tablet coating machine is relatively simple where the application of coating material is done on a moving bed of tablets and removing rapidly the solvent using a current of hot air.
For the tablets to be coated they are placed in a closed drum which is made to rotate continuously in an orbital manner under the influence of a streamlined plate. During the orbital motion of the tablets, the coating medium sprays automatically in a rational manner in order to avoid excess coating on the tablets.
Angled baffles are also fitted into the drum and also air flow is provided which acts as a means to mix the tablets. The baffles cause the tablets to be lifted and turned from the sides of the drum and onto the center exposing all the sides of the tablets to the sprayed coating. Whilst the spraying is going on, hot air is introduced from the 50% perforated tablet bed which causes rapid drying of the coating medium. The hot air comes from inlet fan and is regulated in terms of temperature and volume.
The regulation of the air allows for maintenance of the drum pressure relative to that of the outside room for the purpose of providing a completely isolated process atmosphere. The regulation of the air also provides controlled drying and tablet extraction rates. It also allows for an evenly spread medium on the tablets giving the tablets a smooth solid surface. Tablet coating machine may include coating pans, spraying guns, exhaust and heating pipes. The process may include film coating or sugar coating.
The process is also done in batches which include several phases such as batch identification and selection of the recipe to be used. Loading of the required raw materials, warming, spraying of the coating which is coupled with rotation of the tablets, drying, cooling and lastly unloading of the coated tablets.
Related: Working and Principle of Rapid Mixer Granulator (RMG)
One would wonder what the importance of coating tablets is. Coating machine allows the drug release to be regulated. This ensures that the drug is supplied to the body in safe amounts that the body can handle and also optimizes their effect on the body.
The coating also increases the stability of the tablets which prevents oxidative degeneration caused by factors that may react with the drug such as light and air.
Another advantageous factor of tablet coating is that the tablets can easily be swallowed as they overcome the poor taste the tablets may have. The coating may be flavored or tasteless. This is because some tablets taste bitter or may not have a very pleasant taste.
The coating also gives the tablets its signature color which allows for easy identification and also compatibility with other drugs. The coating also protects the drug from a gastric environment allowing it to reach the area in which it is intended for absorption.
There are parameters which are considered in coating machines. These parameters include air capacity, coating composition, the surface area of the tablet and lastly the efficiency of the equipment.
Usage:
The tablet coating machine is mainly used in pharmaceutical and food industries. Featuring mechatronics and conforming to the requirement of GMP, it is a high efficiency, energy saving, safe and clean equipment for coating tablets, pills and candies with organic film, water soluble film, slow and controlled release film, sugar film and etc.
The tablet cores to be film coated make continuous complicated orbital motion within the closed rotating drum under the action of a streamline guide plate. During the motion, coating medium automatically sprays according to the technological process and rational technological parameters, at the same time hot air is supplied under a negative pressure.
The hot air penetrates through the tablet core layers and is discharged form the bottom of the layers, so that the coating medium sprayed on the surface of tablet cores will dry rapidly and evenly, thus forming a solid and smooth surface film.
All the operations, including expansion of PLC module, setting and control of hot air temperature and adjustment of drum SERIES HIGH-EFFICIENT speed, are carried out on the touch keys of control panel of computer, and the operating panel is a fully closed light touch film interface which does not influence the cleaning of main machine, thus featuring reliable work, stable performance and conforming to the requirement of GMP.
The peristaltic pump with constant pressure variable eliminates the need for a return pipe. The turning radius of the drum varies along with the pressure change. The output slurry and the quantity of slurry sprayed are balanced automatically, thereby stabilizing the effect of atomization, simplifying the spray system, preventing the spray gun from plugging-up, and saving the coating material, moreover the cleaning is simple, and there is no dead corner.
The spray gun specially designed for the film coating machine features even atomization and large coverage of spraying. The universal adjustable spray head makes the cleaning mechanism of spray gun unaffected by charge quantity, so that film coating can proceed continuously, thus reducing the film coating time and saving film coating material.
Accessory and equipment for the coater