Gate Valve (Sluice Valve) Explained

12 Aug.,2024

 

Gate Valve (Sluice Valve) Explained

Introduction

Gate valves are some of the most common valves currently employed. Other common types include the plugbutterflyball and globe type valves.

Read more

Gate Valve Cross-Section

Gate valves are used to start and stop flow, but are poorly suited for regulating (throttling) flow. Flow through a gate valve is not proportional to the amount the gate valve is opened, that is the main reason gate valves are poorly suited to throttling. If the valve is throttled, flow through the valve has a very turbulent and high velocity, this leads to seat and disc wear.

Gate valves offer almost no resistance to flow when they are in the open position; consequently, the pressure differential across the valve is very low when the valve is open.

Like most valves, the gate valve is named after the disc it employs.

Gate valves are always linear motion valves and not rotary motion i.e. they require more than a ¼ turn in order to move from the open to closed position.

As with other valve designs, the gate valve design can be split into several sub-categories. The first category is based upon the disc shape, which is either wedge or parallel shaped. The second category is for either rising, or non-rising stem designs. Other categorisations are based upon the type of disc used:

  • Solid (wedge)
  • Flexible (wedge)
  • Split (wedge)
  • Parallel (parallel)

 

Enjoying this article? Then be sure to check out our Introduction to Valves Video Course! The course has a quizhandbook, and you will receive a certificate when you finish the course. Enjoy!

 

Construction

A gate valve&#;s main components are the bonnetdiscseatsealing arrangement (gland sealstuffing box etc.), stembody and actuator.

Gate Valve Components

Gate valves can be actuated manually (handwheel) or electrically using a high torque motor.

The sliding gate (disc) can be wedge shaped (tapered) or parallel shaped. Wedge shape designs include the solid, flexible and split wedge designs.

Seat rings are used to make replacement of a worn/leaking seat easier. Seat rings have a screw thread on the reverse side which can be screwed into the main valve body, the flat surface on the opposite side is the seating surface area that presses against the disc. If seat rings are not used, it is possible to machine a flat seat on the main valve body itself, unfortunately this makes replacing the seat impossible and the seat can only be machined a few times before the entire valve must be replaced.

Gate valve bonnets are often constructed of cast iron. Cast iron is brittle and this makes the bonnet prone to cracking.  Special care should be taken when handling and maintaining valves with cast iron bonnets.

 

As the stem penetrates through the valve bonnet, it is necessary to install a sealing gland to prevent leakage occurring through the gap between the stem and bonnet; sealing is usually achieved using a fibrous packing material.

Flanges are installed on the suction and discharge side of the valve so that piping can be easily connected.

 

How Gate Valves Work 

The below video is an extract from our Introduction to Valves Online Video Course.

 

The sliding gate (disc) is lowered at a right angle into the flow path until it reaches the valve seat where it seals and stops the flow completely. To open the valve, the sliding gate is retracted into the bonnet.

 

Service Conditions

Gate valves are typically employed for temperatures between -20 to 60 °C, pressures up to 16 bar(g) and flow rates of between 5 (liquids) to 20 (gasses) metres per second. Higher pressures cannot be achieved as damage to the packing would occur.

 

Rising and Non-Rising Stem Designs

Gate valves are classified as rising, or, non-rising stem. `Rising` refers to the stem and if it rises out of the valve bonnet as the valve is opened.

Rising Gate Valve

&#;Non-rising&#; refers to the stem not rising from the valve bonnet irrespective of the valve position.

Non-Rising Gate Valve

Rising stem designs remove both the disc and the stem from the flow path when the valve is open. Non-rising stem designs usually leave the stem within the flow path when the valve is open, although it is also possible to house the stem completely within the disc.

The non-rising stem gate valve is preferred if the ambient environment is corrosive e.g. sea spray etc. and it is not desirable to leave the stem permanently exposed when the valve is open. Conversely, if the flowing medium is corrosive, the non-rising valve may not be a good choice because the stem remains within the flow path when the valve is open.

For non-rising stems, the stem rotates within the packing but does not move vertically, thus there is little risk of dirt or foreign particles damaging the packaging or entering the system.

Non-rising valves are almost always fitted with a local visual pointer which indicates the position of the valve.  The rising stem design is preferred if quick local visual indication is desired (it is easy to identify if the valve is open or closed with the rising stem design).

 

Inclined Disc Designs

Solid Wedges

Solid wedges are the simplest, strongest and most suitable for many flowing mediums. Solid wedges are often manufactured from a single metal piece and the disc seat area size matches the valve seat area size.

Flexible Wedges

You will get efficient and thoughtful service from Yaxing Valve.

Flexible wedges are machined around the wedge perimeter in order to help the disc locate the seating surface more easily. The size of the machined area should not be too large as this reduces the strength of the disc (a thinner disc is a weaker disc).

Flexible wedges are employed for systems operating with large temperature fluctuations. As the system temperature changes, the piping and valve dimensions also change due to the coefficient of thermal expansion. Having a flexible/variable seating area allows the valve to seat correctly even with some expansion and contraction of parts.

Flexible Wedge Example

A solid wedge valve is installed within a steam system. If the valve is in the closed position when the system is hot, the wedge may become locked/jammed against the valve seat once the valve components temperature decreases. This renders the valve totally inoperable and it will remain in the closed position until the system temperature again reduces, or, until all valve parts reach the same temperature. This type of problem is referred to as &#;valve binding&#;.

Split Wedge

Split wedges offer flexible seating on both the suction and discharge side of the wedge. The wedge consists of two separate halves with each one being able to self-align in order to seat correctly; this self-aligning feature is made possible due to the flexibility obtained when using two separate halves for one wedge.

Parallel Disc Design

Parallel Disc

Parallel sliding discs utilise a spring placed between the two parallel discs. The spring is held under compression between the parallel discs and thus exerts constant force outwards onto the internal surfaces of the discs. As the valve is lowered into the valve seat, the spring is further compressed and the resultant force exerted by the spring ensures each disc is pressed firmly against the seat.

Parallel disc type valves can be used for both high and low pressure applications. The valve is well suited for any system where there are large temperature fluctuations.

 

Advantages

The gate valve is very simple in design, relatively cheap and easy to maintain.

There is almost no pressure drop across the valve when the valve is in the fully open position.

Replacement of the gate valve disc is usually not a difficult task.

Replacement of the seat rings is usually not a difficult task.

 

Disadvantages

Gate valves are not well suited to throttling (any valve position between fully open and fully closed) as this creates turbulent flow and frictional losses. A valve left in the almost closed position will cause the flowing medium to flow at very high velocity across the valve&#;s seating surfaces, this can lead to damage of the surfaces (&#;wire-drawing&#;) and passing/leaking of the valve.

Gate valves create turbulent flow when throttled and experience excessive vibration as a result. This situation should be avoided to prevent damage occurring to the valve packing and other internal parts.

Compared to a globe valve, a gate valve&#;s seating surfaces are more difficult to refurbish (if seat rings are not used).

 

 3D Model Details

This 3D model shows all major components associated with a typical gate valve, these include:

  • Handle/Actuator
  • Stem
  • Bonnet
  • Body
  • Gate/Disc
  • Seat

 

Additional Resources

https://en.wikipedia.org/wiki/Gate_valve

https://www.avkvalves.eu/en/insights/product-insights/gate-valves/what-is-a-gate-valve

Sluice Valve Vs Gate Valve

Valves are very important components in utility systems. A gate valve, as the name suggests, is a type of valve used to control the flow of a liquid using a gate or plate. This type of valve is mainly used to stop or start the flow completely and is not used to regulate the flow amount unless specifically designed.

The best industrial valve manufacturers follow stringent standards while manufacturing these valves to ensure quality, durability, and performance. Any sub-standard quality may lead to unwanted damage and economic losses. Efficiency and ease of operation are two very important factors when choosing a valve from the many available valves.

A Sluice valve is called a gate valve; look through it for more information about them.

What is a Sluice Valve?

A gate valve or a Sluice gate valve is described as a valve that uses a gate or wedge shape disk that slides perpendicular to the fluid flow into or out of the pipeline. When the gate valve is fully opened, the disk of the gate valve is completely separated from the flow. This practically gives no opposition to flow. Due to this, very little reduction in pressure is experienced as the fluid moves through the gate valve.

The sluice gate valve is the common type of valve that is used in process plants to handle slurries. In operation, these valves are either fully opened or fully closed.

Sluice gate valves cannot be used for throttling as accuracy cannot be achieved using them. The high flow velocity in the partially open valve can cause disk and seat surface erosion and can also cause vibration and noise.

Sluice Valve Function

Sluice Valve and/or Gate Valve functions strictly to start or stop the flow. Gate valves are used for the water supply system, and sluice valves are used for slurries. The gate valve is opened by lifting the gate/wedge from the water flow, allowing all water to pass without resistance. The top end of the stem (connecting rod/shaft) has a hand wheel or motor to lift and drop the gate, and its bottom end has a gated circular or wedge-shaped to block the water flow. It has a threaded stem; hence the valve has to turn multiple times to go from the open to the closed position, preventing water hammer effects.

Sluice Valve Parts

  • Gate
    • Available in various designs, the gate is the main part of a gate valve. The main design aspect of it is its sealing capacity for specific applications. A gate valve can be classified as parallel or wedge-shaped based on the gate type. The former can be divided into slab, parallel slide, and parallel expanding gates.
  • Seats
    • A gate valve has two seats that ensure sealing along with the gate. These seats can be integrated within the valve body or as a seat ring. The latter is threaded or pressed into its position, then sealed and welded to the valve body. In situations where the valve is subject to higher temperatures, seat rings are preferred, as they allow for more variation in design.
  • Stem
    • The gate in a gate valve is lowered or raised when it spins on a threaded system. This can take place via a manual wheel or an actuator. An actuated gate valve can be controlled remotely. Depending on the step type, the gate valve can be categorized into rising stem and non-rising stem valves. The former is fixed to the gate, whereas the latter is to the actuator and threaded into the gate.
  • Bonnets
    • Bonnets are valve components that ensure the safe sealing of the passage. It is either bolted or screwed to the valve body so that it can be removed for replacement or maintenance. Based on application, various valve bonnets include bolt bonnets, screw-in bonnets, union bonnets, and pressure seal bonnets.

Types of Sluice Valves

Rising and Non-Rising Stem Designs

Gate valves are classified as rising or non-rising stems. Rising refers to the stem and if it rises out of the valve bonnet as the valve is opened.

&#;Non-rising&#; refers to the stem not rising from the valve bonnet, irrespective of the valve position.Rising stem designs remove both the disc and the stem from the flow path when the valve opens. Non-rising stem designs usually leave the stem within the flow path when the valve is open, although it is also possible to house it completely within the disc.

Inclined Disc Designs

Solid Wedge Gate Valves

Solid wedges are the simplest, strongest, and most suitable for many flowing mediums. Solid wedges are often manufactured from a single metal piece, and the disc seat area size matches the valve seat area size.

Flexible Wedge Gate Valves

Flexible wedges are machined around the wedge perimeter to help the disc locate the seating surface more easily. The machined area should not be too large as this reduces the disc&#;s strength (a thinner disc is weaker).

Split Wedge Gate Valves

Split wedges offer flexible seating on both the suction and discharge side of the wedge. The wedge consists of two separate halves, each able to self-align to sit correctly; this self-aligning feature is made possible due to the flexibility obtained when using two separate halves for one wedge.

Parallel Disc Gate Valves

Parallel sliding discs utilize a spring placed between the two parallel discs. The spring is held under compression between the parallel discs and thus exerts constant force outwards onto the internal surfaces of the discs. As the valve is lowered into the valve seat, the spring is further compressed and the resultant force exerted by the spring ensures each disc is pressed firmly against the seat.

Sluice Valve Vs Gate Valve

Sluice valves and gate valves are somewhat different in operation and usage. A gate valve can be a good option for in-line sealing and sludge applications. But when it is needed for managing the flow in a sluice or stream, the sluice gate valve is the best option for your application.

Good quality and efficient valves like the ones by ZECO are a great investment as it requires minimal maintenance in the long run, which can save a lot of money. Contact ZECO Valve today for best-in-class valves.

Contact us to discuss your requirements of Gate Valve and Sluice Valve. Our experienced sales team can help you identify the options that best suit your needs.