Disadvantages Of Fire Fighting System - VariEx

26 Aug.,2024

 

Disadvantages Of Fire Fighting System - VariEx

While fire fighting systems are essential for protecting lives and property from the devastating effects of fires, they also have certain limitations and disadvantages. Understanding these drawbacks is crucial for effectively managing fire risks and implementing appropriate safety measures. Here are some common disadvantages associated with fire fighting systems. 

If you want to learn more, please visit our website JIANZHI.

  1. Limited Effectiveness Against Certain Types of Fires:

    • suppression systems, for example, may not be suitable for extinguishing electrical fires due to the risk of electrical shock.

      Fire fighting systems may be less effective against certain types of fires, such as electrical fires or fires fueled by flammable metals. Water-based, for example, may not be suitable for extinguishing electrical fires due to the risk of electrical shock.

  2. Potential Water Damage:

    • Water-based fire suppression systems, such as sprinklers or hose reels, can cause water damage to property and equipment, even if they successfully extinguish the fire. This can result in costly repairs and downtime for businesses.

  3. False Alarms and Malfunctions:

    • Fire detection and alarm systems may be prone to false alarms or malfunctions, leading to unnecessary evacuations, disruptions, and loss of productivity. Malfunctions in fire suppression systems can also occur, compromising their effectiveness during emergencies.

  4. Maintenance and Inspection Requirements:

    • Fire fighting systems require regular maintenance and inspection to ensure they are in proper working condition. This can be time-consuming and costly for building owners and managers, particularly for larger systems or systems with complex components.

  5. Dependency on External Factors:

    • The effectiveness of fire fighting systems may depend on external factors such as water supply availability, power supply reliability, and accessibility for emergency responders. In remote areas or during natural disasters, these factors can pose challenges for fire suppression efforts.

  6. Environmental Concerns:

    • Some fire suppression agents, such as certain types of fire retardants or chemicals used in gas-based suppression systems, may pose environmental risks or contribute to air and water pollution. Careful consideration of environmental impacts is necessary when selecting and using fire fighting systems.

  7. Cost Considerations:

    • The installation, maintenance, and operation of fire fighting systems can be costly, particularly for larger or more complex systems. Building owners and managers must weigh the costs against the potential benefits of fire protection when planning their budgets.

  8. Occupant Safety Concerns:

    • In rare cases, fire fighting systems may pose safety risks to building occupants, such as accidental activation of sprinkler systems causing slips and falls, or exposure to suppression agents causing respiratory irritation. Proper training and education are essential to mitigate these risks.

Despite these disadvantages, fire fighting systems remain essential for protecting lives and property from fire-related hazards. It is essential to carefully evaluate the specific risks and requirements of each building or facility and implement appropriate fire protection measures to minimize the potential drawbacks associated with fire fighting systems. Regular training, maintenance, and periodic reviews of fire safety plans are essential for ensuring the effectiveness and reliability of fire protection measures over time.

Frequently Asked Questions

  1. What are fire fighting systems, and why are they important?

    • Fire fighting systems are designed to detect, suppress, and extinguish fires to protect lives and property. They are essential for minimizing the impact of fires and ensuring the safety of occupants within buildings and facilities.

  2. What are the different types of fire fighting systems available?

    • Common types of fire fighting systems include fire detection and alarm systems, fire suppression systems (such as sprinkler systems, gas-based systems, and foam systems), and fire extinguishers. Each system is designed to address specific fire hazards and environments.

  3. How do fire detection and alarm systems work?

    • Fire detection and alarm systems use sensors, detectors, and alarm devices to detect signs of fire, such as smoke, heat, or flames. Once a fire is detected, the system activates alarms to alert occupants and trigger appropriate emergency response actions.

  4. What is the role of fire suppression systems in fire protection?

    • Fire suppression systems are designed to suppress or extinguish fires once they are detected. These systems use various agents, such as water, gas, or foam, to smother or cool the fire and prevent its spread.

  5. How often should fire fighting systems be inspected and maintained?

    • Fire fighting systems should be inspected and maintained regularly to ensure they are in proper working condition. The frequency of inspections and maintenance depends on factors such as system type, usage, and regulatory requirements.

  6. What should I do in the event of a fire alarm activation?

    • In the event of a fire alarm activation, occupants should follow established emergency procedures, evacuate the building via designated escape routes, and assemble at designated assembly points. It is essential to remain calm and follow the instructions of trained personnel.

  7. Can fire fighting systems cause false alarms?

    • Yes, fire fighting systems, particularly fire detection and alarm systems, can occasionally experience false alarms due to factors such as dust, steam, or cooking fumes triggering the sensors. Proper system maintenance and sensitivity adjustments can help minimize false alarms.

  8. Are fire fighting systems environmentally friendly?

    • While fire fighting systems play a crucial role in fire safety, some suppression agents and system components may have environmental impacts. It is essential to select systems and agents that minimize environmental risks and comply with relevant regulations.

Fire Sprinkler System Pipe Material: Steel Pipe Pros, Cons ...

Understanding NFPA mandates and the benefits and drawbacks of steel fire sprinkler pipe

Automatic fire sprinkler systems are installed or retrofitted in nearly every type of property, from hotels to offices to single-family homes. Thus, fire sprinkler system pipe material must be versatile, easy to install, cost-effective, and&#;above all&#;reliable to meet the needs of this diverse market.

Steel has traditionally been the material of choice for fire sprinklers, although thermoplastic pipes now dominate residential and other light-hazard categories. But with so many choices&#;and so much at stake&#;how do you know which fire sprinkler pipe will stand up best to the unique demands of your property during a fire?

Previously, we have examined piping trends in home sprinkler systems. In this blog, we explore the pros and cons of one of the most popular piping materials for commercial systems&#;steel&#;to help you make an informed choice. You can also check out this blog that examines CPVC and copper fire sprinkler pipe.

Feel free to check out our selection of piping components and installation tools such as CPVC pipe fittings, hangers, sealants, and gaskets and flange packs, as well as other parts and accessories for commercial and residential sprinkler systems.

NFPA permits listed metallic and nonmetallic fire sprinkler pipe

Before we examine the types of pipe, let&#;s provide some perspective. The edition of NFPA 13: Standard for the Installation of Sprinkler Systems (7.3.1.1) permits listed metallic and nonmetallic materials for sprinkler pipe and tubing that meet or exceed the following American Society for Testing and Materials (ASTM) standards:

But read this carefully: not all pipe or tubing that meets these standards is also listed for fire sprinkler service. Pipes that are &#;listed&#; have been rigorously tested and found to meet the safety standards of a third-party certification agency. Metal pipes are listed to UL 852 and thermoplastic pipes are listed to UL .

Listed pipes are easily identified by the listing agency&#;s logo. If listed materials differ from Table 7.3.1.1, NFPA 13 permits their use as long as installers adhere to any limitations in the listing. To ensure there are no mistakes, NFPA 13 requires manufacturers to include listing limitations in their installation instructions.

For more information, please visit fire fighting fittings.

From the edition of NFPA 13

7.3.2 * Nonmetallic pipe and tubing

7.3.2.1 Nonmetallic pipe in accordance with Table 7.3.1.1 shall be investigated for suitability in automatic sprinkler installations and listed for this service.

7.3.2.1.1 Other types of nonmetallic pipe or tube investigated for suitability in automatic sprinkler installations and listed for this service, including but not limited to CPVC, and differing from that provided in Table 7.3.1.1 shall be permitted where installed in accordance with their listing limitations.

7.3.2.1.2 Manufacturer&#;s installation instructions shall include its listing limitations.

7.3.3 * Listed Metallic Pipe and Tubing.

7.3.3.1 Other types of pipe or tube investigated for suitability in automatic sprinkler installations and listed for this service, including steel, and differing from that provided in Table 7.3.1.1 shall be permitted where installed in accordance with their listing limitations, including installation instructions.

But while NFPA 13 determines which piping materials are acceptable overall&#;and safety organizations such as UL (formerly Underwriter Laboratories) specify which ones will perform reliably at different hazard levels&#;property owners can still choose among several materials for commercial applications.

First, determine which hazard level your property falls into. Most offices, for instance, are &#;light hazard&#; and can choose any of these pipes, but businesses that regularly contain more combustible materials such as doctors&#; offices, restaurants, food stores, and manufacturing plants have higher hazard levels and thus cannot use thermoplastic pipes.

The table below sums up important differences between the most popular piping materials:

Let&#;s dig deeper into the pros and cons of these fire sprinkler system pipe materials, starting with steel:

Black steel dominates the fire sprinkler market, but corrosion is a serious concern

Since the first fire protection systems were installed, the strength, durability, and extreme resistance to heat exhibited by black steel has made it the traditional leader of the fire sprinkler pipe market. With a melting point that falls between a whopping 2,600°F and 2,800°F (1,427°C and 1,538°C), steel pipe can withstand the heat of a burning building and keep water flowing onto a fire.

Steel pipe is suitable for all fire protection systems. It&#;s easily formed, bent, and fabricated, enabling it to be manufactured into various sizes, shapes, and configurations.

It also boasts the lowest coefficient of thermal expansion among fire sprinkler system pipe materials. This coefficient describes how the size of an object changes with a temperature change. For instance, a 100-foot section of steel pipe will only expand 0.63 of an inch when heated from 40°F to 120°F, minimizing the need for expansion loops and joints, according to a National Institute of Standards and Technology (NIST) report. By comparison, while copper carries the next-best coefficient of thermal expansion, it&#;s still 1.5 times higher.

Steel offers many other benefits as well. Extended exposure to ultraviolet light has no impact on its mechanical properties or performance. It can also be painted with no adverse effects.

Steel&#;s strength and rigidity mean that dropping, stepping on, or banging steel pipes during installation will not easily cause damage, which can be a concern with CPVC. Rigidity is also important because it determines the distance between hangers during installation. More flexible materials require more hangers, upping the cost of that component of an installation.

Steel&#;s rigidity creates challenges, however, when pipe must be routed around obstacles during installation. Rigidity exerts high forces on anchors as well. Steel is also the heaviest material, increasing the difficulty of installation because more people are often needed to move it.

For decades, sprinkler pipe was predominantly schedule 40 black steel pipe. But in the mid-s, a fencing manufacturer, Allied Tube and Conduit, sparked a long debate about the necessary pipe wall thickness for fire protection. Allied wanted to expand its business by applying the thinner but strong and durable steel pipe it used for fences to fire sprinklers. And since sprinkler water is essentially stagnant until a fire occurs, it argued, why couldn&#;t thinner pipe be used?

Eventually, the NFPA paved the way for the acceptance of thinner&#;and thus lighter weight&#;steel pipes by adding a provision to its standard that allows any material certified by a testing laboratory to be used in sprinkler systems.

From the edition of NFPA 13

16.3.4 Specially Listed Steel Pipe. Pressure limitations and wall thickness for steel pipe specially listed in accordance with 7.3.3 shall be permitted to be in accordance with the pipe listing requirements.

But steel pipes have a major drawback: they are more susceptible to corrosion than any other fire sprinkler system pipe material, and damage can begin as soon as a system is installed. The presence of water, oxygen, and metal creates the ultimate breeding ground for rust to form. This &#;corrosion triangle&#; also contributes to microbiologically induced corrosion (MIC), allowing bacteria to colonize the internal surfaces of steel pipes.

Corrosion prompts costly service calls to fix obstructed pipes, repair leaky holes, and remove loose scale or rust that clog sprinklers and valves and degrade the system&#;s flow characteristics. Steel&#;s susceptibility to corrosion-caused pitting and buildup earns it the lowest hydraulic C-factor, which measures the roughness on the inside of pipes and its ability to impede water flow. Black steel pipes have a C-factor of 120 in wet systems, while the more corrosion-resistant copper and CPVC pipes boast C-factors of 150.

Left untreated, corrosion triggers leaks or accidental sprinkler discharges, potentially causing tens of thousands of dollars in water damage to the property the system was meant to protect. And it can cause fire sprinklers to fail during a fire.

The problem is the most severe in dry sprinkler systems which rely on pressurized air to hold back the water supply and keep pipes from freezing in cold temperatures. Water isn&#;t supposed to enter dry pipes until sprinkler heads activate. But condensation and the annual trip test required by NFPA 25: Standard for the Inspection, Testing, and Maintenance of Water-Based Fire Protection Systems make it nearly impossible to keep dry systems completely dry. The C-factor of steel drops to 100 in dry systems.

More than 70 percent of dry sprinkler systems suffer significant corrosion issues within 12.5 years of installation, according to a Potter Corrosion Solutions report. But that doesn&#;t mean wet systems escape unscathed: 35 percent of them experience significant issues after 25 years.

NFPA 13 (A.7.3.3) notes that corrosion generally impacts steel pipes with thinner walls the fastest, reducing their effective lifespan compared to thicker schedule 40 pipes.

Replacing pressurized air with nitrogen in dry systems can dramatically improve the lifespan of steel pipes by eliminating a critical leg of the corrosion triangle. Read our previous blog to learn more about the benefits of nitrogen for dry systems. You can also check out our guide to mitigating and fixing corrosion in fire sprinkler pipe.

While effective for preventing corrosion in other uses, galvanized steel fails faster in fire sprinklers

Two decades ago, galvanized steel was touted as a miracle solution against the impact of corrosion on metal pipes. Galvanized steel pipes are coated with zinc. Since zinc is more reactive than steel, it&#;s intended to serve as a sacrificial material when corrosion strikes, creating a protective layer of scale build-up while protecting the piping underneath.

The theory was so widely accepted that the NFPA considered a requirement that all steel pipe used in dry sprinklers systems be internally galvanized.

But here&#;s the thing: while galvanized steel can be an excellent means of preventing corrosion on street signs and guard rails where it&#;s given the opportunity to dry out, persistently moist, oxygenated conditions cause it to corrode aggressively, according to a Sprinkler Age report. Studies have shown pinhole leaks developing in dry systems with galvanized steel pipes within two years of installation&#;and ruptures within four years, according to Potter Corrosion Solutions.

Even worse, the corrosion process causes galvanized steel to shed Zn2+ ions into the discharge water when dry or preaction sprinkler systems are tested, creating a heavy metal contamination environmental hazard. Sprinkler Age reports that many municipalities prohibit discharges of water containing more than 30 mg/L of Zn2+, and most discharged water from galvanized dry and preaction fire sprinkler systems contains -plus mg/L of Zn2+.

In , NFPA 13 reversed a previous decision to boost the hydraulic C-factor of galvanized steel pipes in dry systems from 100 to 120, recognizing that it did not offer any more corrosion benefits than bare black steel pipe. Galvanized steel retains its C-factor of 120 in wet systems.

In , NFPA 13 also removed its requirement that steel pipe used with control mode specific application (CMSA) sprinklers must be internally galvanized, a mandate that had been in place since large drop sprinklers were first permitted for dry pipe systems in .

Other standards followed suit. In , the U.S. Department of Defense banned the use of galvanized steel piping in the majority of its fire protection systems. It also required black steel to replace galvanized steel when additions, replacements, or relocations are made. A year later, the U.S. Government Services Administration prohibited galvanized steel pipes in dry sprinkler systems.

Once again, it&#;s important to note that removing oxygen from dry systems and replacing it with pressurized nitrogen can significantly increase the lifespan of galvanized pipes&#;enabling property owners to enjoy the many other benefits of this steel in their fire sprinklers. NFPA 13 also maintains that galvanized steel pipe, fittings, and hangers might be suitable for exterior uses &#;when moisture conditions are severe but corrosive conditions are not of great intensity&#; (A.16.4.2.1). It adds, however, that exposed material should be given a protective paint coating.

At the end of the day, NFPA 13 has not banned listed galvanized steel from fire sprinkler pipes. It references its use for other specific applications as well, including cooling tower fire sprinklers, marine supply system piping, and piping to water motor-operated devices and pressure-actuated alarm-initiating devices.

Stay tuned to learn about more types of fire sprinkler pipe

Using the right pipes is essential to your fire sprinkler&#;s ability to control and extinguish a fire&#;and steel is a commonly used fire sprinkler system pipe material that&#;s a good choice in many applications, as long as the potential for corrosion is accounted for.

Our next installment of this series on fire sprinkler pipe material covers two other popular choices:

  • Copper pipe: More expensive than steel but it&#;s smoother and more resistant to corrosion.
  • CPVC pipe: Inexpensive, flexible, and it has the highest corrosion resistance&#;but it&#;s only for use in light-hazard settings

Looking to install sprinkler pipes? Check out our selection of piping components such as CPVC pipe fittings, hangers, sealants, and gaskets and flange packs, as well as other parts and accessories for commercial and residential sprinkler systems.

Questions about QRFS products or need a brand or item not in our online inventory? Just call us at +1 (888) 361- or .

This blog was originally posted at blog.qrfs.com. Check us out at Facebook.com/QuickResponseFireSupply or on Twitter @QuickResponseFS.

Contact us to discuss your requirements of elbow pipe. Our experienced sales team can help you identify the options that best suit your needs.